Product-family imageASA SANTERNO industrial soft starter
Santerno’s static soft starter for controlled starting and stopping of three-phase induction motors, spanning 5.5 to 600 kW.
Final configuration, availability and supply terms are confirmed after reviewing project requirements.
Model selection & inquiryProduct-family overview
The ASA soft starter is a static starter for three-phase induction motors from 5.5 to 600 kW, with a 200–690 V voltage range and 11–1200 A current range. Several starting methods are supported (voltage/torque ramp, current limitation and current ramp) along with soft stop on a timed voltage ramp. Modbus RTU communication, a multilingual graphic display and counters for starts, operating hours and consumed energy are included; its main benefits are lower inrush current, reduced supply-voltage dip and less mechanical stress on couplings, gearboxes, pumps, fans and conveyors.
- Power range 5.5–600 kW at 200–690 V and 11–1200 A
- Multiple starting methods and timed voltage-ramp soft stop
- Modbus RTU with start, operating-hour and energy counters
- Brand
- SANTERNO
- Product category
- Soft starters
- Related services
- Selection, commissioning & support
Selection information
- Motor nameplate and supply voltage
- Load type and starting frequency
- Panel conditions and existing protection equipment
Related services
Send the equipment model, motor nameplate, load type and installation conditions to the technical team. Power, voltage and features must be confirmed in the documentation of the exact model.
Frequently asked questions
- Which technical documents are available for ASA?
- The following verified documents are recorded for ASA: hardware manual. They can be downloaded from the catalog and manuals section on this page.
- What is needed for a price and availability quote?
- Send the equipment model, a motor nameplate photo, the load type and installation conditions through the contact page. Final configuration and supply terms are confirmed after the project requirements are reviewed.
- How is the ASA model selected?
- Selection is assessed against: Motor nameplate and supply voltage; Load type and starting frequency; Panel conditions and existing protection equipment.
Catalog & manuals · ASA
Download the catalog, hardware manual (HW) and firmware manual (FW) for each family directly from the links below. Each PDF can be saved; check that the document matches your equipment model and version before use.
Catalog
No working verified link is recorded for this section in the official source.
Hardware manual
Firmware manual
No working verified link is recorded for this section in the official source.
Here for your next project.
Share your project requirements or equipment details. We support you from selection to commissioning.
Talk to an expert